{"product_id":"osburn-3500-epa-certified-freestanding-extra-large-wood-stove-with-blower","title":"Osburn 3500 EPA Certified Freestanding Extra Large Wood Stove with Blower","description":"\u003ciframe title=\"OSBURN | Wood Stoves 1700 | 2000 | 3300 | 3500\" src=\"https:\/\/www.youtube.com\/embed\/YECUZm9DPdA\" height=\"300\" width=\"100%\" loading=\"lazy\"\u003e\u003c\/iframe\u003e\n\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eThe Osburn 3500 EPA Certified Freestanding Extra Large Wood Stove with Blower delivers powerful, efficient heating for larger homes and open living spaces. Producing up to 110,000 BTU\/h, this high-performance wood-burning stove heats areas ranging from 1,000 to 2,700 square feet. Its spacious 3.5 cubic foot firebox accommodates logs up to 22 inches long and provides a maximum burn time of 10 hours under optimal conditions. Featuring EPA 2020-certified non-catalytic combustion with average particulate emissions of just 1.6 g\/h, the Osburn 3500 delivers cleaner, more efficient wood heating. An included 130 CFM blower helps distribute warm air throughout the room for enhanced comfort.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan\u003eBuilt for durability and dependable performance, the Osburn 3500 features a heavy-duty steel body, reinforced 5\/16-inch steel top, and refractory brick-lined firebox for improved heat retention and distribution. Its advanced stainless-steel secondary air system promotes more complete combustion and better fuel efficiency, while the C-Cast baffle supports efficient burning. The large ceramic glass viewing window, surrounded by a durable cast iron door frame, offers an impressive view of the flames. An integrated air-wash system helps reduce soot buildup on the glass, combining traditional wood-burning ambiance with modern heating technology.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan\u003eMeasuring 28.875\" W x 34.75\" H x 33.5\" D, the Osburn 3500 Extra Large Wood Stove features a sturdy pedestal design that complements a variety of residential interiors. Its 6-inch flue outlet requires a compatible chimney system with a minimum height of 15 feet. Approved for alcove installations and mobile homes when equipped with the required fresh air intake, this versatile freestanding wood stove offers flexible installation options when installed according to manufacturer specifications. Backed by a limited lifetime warranty, the Osburn 3500 combines exceptional heating capacity, durable construction, and efficient combustion for lasting comfort.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cspan\u003eOsburn 3500 Wood Burning Stove\u003c\/span\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cspan\u003ePedestal with Ash Drawer\u003c\/span\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cspan\u003eBlower (130 CFM)\u003c\/span\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cspan\u003eOwner's Manual\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan\u003eRequired Accessories\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cspan\u003eDoor Overlay\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan\u003eOptional Accessories\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRigid Firescreen\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e5\" Fresh Air Intake Kit for Wood Stove on Pedestal\u003c\/li\u003e\n  \u003cli\u003e5\" Fresh Air Intake Register with Airtight Damper\u003c\/li\u003e\n  \u003cli\u003e5\" x 4' Insulated Flex Pipe for Fresh Air Intake\u003c\/li\u003e\n  \u003cli\u003eGlass Ash Lip\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBlower included, up to 130 CFM\u003c\/li\u003e\n  \u003cli\u003eHeats 1,000 to 2,700 sq ft with up to 110,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e3.5 cu ft firebox that takes logs up to 22\"\u003c\/li\u003e\n  \u003cli\u003eMaximum burn time of 10 hours\u003c\/li\u003e\n  \u003cli\u003eEPA 2020 certified, non-catalytic, 1.6 g\/h average particulate emissions\u003c\/li\u003e\n  \u003cli\u003eCeramic glass door with cast iron frame and glass air-wash system\u003c\/li\u003e\n  \u003cli\u003eApproved for alcove and mobile home installation\u003c\/li\u003e\n  \u003cli\u003e5\/16\" steel top\u003c\/li\u003e\n  \u003cli\u003eLimited lifetime warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n  \u003ctbody\u003e\n    \u003ctr data-order=\"0\" data-spec-id=\"Techno\"\u003e\n      \u003ctd width=\"50%\"\u003eCombustion technology\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eNon-catalytic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"26\" data-spec-id=\"EPA\"\u003e\n      \u003ctd width=\"50%\"\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eYes, EPA 2020 approved\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"33\" data-spec-id=\"LongBuci\"\u003e\n      \u003ctd width=\"50%\"\u003eMaximum log length\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e22\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"34\" data-spec-id=\"PosBuch\"\u003e\n      \u003ctd width=\"50%\"\u003eLog positioning\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eLoading over width and over depth\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"35\" data-spec-id=\"DiaChei\"\u003e\n      \u003ctd width=\"50%\"\u003eChimney diameter\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e6\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"36\" data-spec-id=\"DiaEvaci\"\u003e\n      \u003ctd width=\"50%\"\u003eFlue outlet diameter\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e6\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"38\" data-spec-id=\"TyChei\"\u003e\n      \u003ctd width=\"50%\"\u003eType of chimney\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eCAN\/ULC S629, UL 103 HT (2100 °F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"39\" data-spec-id=\"Hchei\"\u003e\n      \u003ctd width=\"50%\"\u003eMinimum chimney height (feet)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e15'\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"40\" data-spec-id=\"Cfeu\"\u003e\n      \u003ctd width=\"50%\"\u003eBaffle type\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eC-Cast or equivalent\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"41\" data-spec-id=\"Alcove\"\u003e\n      \u003ctd width=\"50%\"\u003eApproved for an alcove installation\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"42\" data-spec-id=\"MaiMob\"\u003e\n      \u003ctd width=\"50%\"\u003eApproved for a mobile home installation\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eYes, with fresh air intake\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"43\" data-spec-id=\"Poidi\"\u003e\n      \u003ctd width=\"50%\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e549 lb (249 kg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"44\" data-spec-id=\"TyPorte\"\u003e\n      \u003ctd width=\"50%\"\u003eDoor type\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eSingle, glass with cast iron frame\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"46\" data-spec-id=\"TyVitre\"\u003e\n      \u003ctd width=\"50%\"\u003eGlass type\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eCeramic glass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"47\" data-spec-id=\"SurfViti\"\u003e\n      \u003ctd width=\"50%\"\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e18 7\/8\" x 11 3\/4\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"48\" data-spec-id=\"AutoCle\"\u003e\n      \u003ctd width=\"50%\"\u003eGlass air-wash system\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"50\" data-spec-id=\"TyVent\"\u003e\n      \u003ctd width=\"50%\"\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e130\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"56\" data-spec-id=\"DimExHHi\"\u003e\n      \u003ctd width=\"50%\"\u003eOverall dimension (Height)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e34 3\/4\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"57\" data-spec-id=\"DimExHLi\"\u003e\n      \u003ctd width=\"50%\"\u003eOverall dimension (Width)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e28 7\/8\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"58\" data-spec-id=\"DimExHPi\"\u003e\n      \u003ctd width=\"50%\"\u003eOverall dimension (Depth)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e33 1\/2\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"59\" data-spec-id=\"DimPorHi\"\u003e\n      \u003ctd width=\"50%\"\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e9 7\/8\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"60\" data-spec-id=\"DimPorLi\"\u003e\n      \u003ctd width=\"50%\"\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e19\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"61\" data-spec-id=\"DimComHi\"\u003e\n      \u003ctd width=\"50%\"\u003eFirebox – dimension (Height)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e12 7\/8\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"62\" data-spec-id=\"DimComLi\"\u003e\n      \u003ctd width=\"50%\"\u003eFirebox – dimension (Width)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e22 7\/8\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"63\" data-spec-id=\"DimComPi\"\u003e\n      \u003ctd width=\"50%\"\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e20 1\/8\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"64\" data-spec-id=\"BriRef\"\u003e\n      \u003ctd width=\"50%\"\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"66\" data-spec-id=\"SysAirSe\"\u003e\n      \u003ctd width=\"50%\"\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"67\" data-spec-id=\"ModSur\"\u003e\n      \u003ctd width=\"50%\"\u003eModel\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003ePedestal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"69\" data-spec-id=\"EpAciCi\"\u003e\n      \u003ctd width=\"50%\"\u003eSteel thickness – body\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e3\/16\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"70\" data-spec-id=\"EpAciDi\"\u003e\n      \u003ctd width=\"50%\"\u003eSteel thickness – top\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003e5\/16\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"126\" data-spec-id=\"NoEmUs\"\u003e\n      \u003ctd width=\"50%\"\u003eUSA standard (emissions)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eEPA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"127\" data-spec-id=\"NoEmCa\"\u003e\n      \u003ctd width=\"50%\"\u003eCanadian Standard (emissions)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eCSA B415.1-10\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"128\" data-spec-id=\"NoSeUs\"\u003e\n      \u003ctd width=\"50%\"\u003eUSA standard (safety)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eUL 1482, UL 737\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"129\" data-spec-id=\"NoSeCa\"\u003e\n      \u003ctd width=\"50%\"\u003eCanadian standard (safety)\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eULC S627\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"130\" data-spec-id=\"TestPar\"\u003e\n      \u003ctd width=\"50%\"\u003eTested and listed as per applicable standards\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eBy an accredited laboratory (CAN\/USA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr data-order=\"131\" data-spec-id=\"Garantie\"\u003e\n      \u003ctd width=\"50%\"\u003eWarranty\u003c\/td\u003e\n      \u003ctd width=\"50%\"\u003eLimited lifetime\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAppliance Performance\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd class=\"p-head-table-spec\" width=\"50%\"\u003eFuel type\u003c\/td\u003e\n      \u003ctd data-spec-id=\"TyComb\" colspan=\"2\" width=\"50%\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd class=\"p-head-table-spec\" width=\"50%\"\u003eRecommended heating area-ft² \u003c\/td\u003e\n      \u003ctd data-spec-id=\"Surfi\" colspan=\"2\" width=\"50%\"\u003e1,000 - 2,700\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd class=\"p-head-table-spec\" width=\"50%\"\u003eOverall firebox volume-ft³\u003c\/td\u003e\n      \u003ctd data-spec-id=\"VolComi\" colspan=\"2\" width=\"50%\"\u003e3.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd class=\"p-head-table-spec\" width=\"50%\"\u003eEPA loading volume-ft³ \u003c\/td\u003e\n      \u003ctd data-spec-id=\"LoadEPA\" colspan=\"2\" width=\"50%\"\u003e2.88\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd class=\"p-head-table-spec\" width=\"50%\"\u003eMaximum burn time \u003c\/td\u003e\n      \u003ctd data-spec-id=\"TempComb\" colspan=\"2\" width=\"50%\"\u003e10 h\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd class=\"p-head-table-spec\" width=\"50%\"\u003eMaximum heat output-dry cordwood \u003c\/td\u003e\n      \u003ctd data-spec-id=\"PWMaSoi\" colspan=\"2\" width=\"50%\"\u003e110,000 BTU\/h (32.2 kW)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd class=\"p-head-table-spec\" width=\"50%\"\u003eOverall heat output rate \u0026lt; \u003c\/td\u003e\n      \u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\" width=\"50%\"\u003e17,200 BTU\/h (5.0 kW) to 57,800 BTU\/h (16.9 kW)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd class=\"p-head-table-spec\" width=\"50%\"\u003eAverage overall efficiency (dry cordwood)\u003c\/td\u003e\n      \u003ctd data-spec-id=\"ReMoyGBmi\" width=\"25%\"\u003e71 % (HHV)\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n      \u003ctd data-spec-id=\"RenMoyGBi\" width=\"25%\"\u003e76 % (LHV)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd class=\"p-head-table-spec\" width=\"50%\"\u003eOptimum overall efficiency\u003c\/td\u003e\n      \u003ctd data-spec-id=\"EffOpti\" colspan=\"2\" width=\"50%\"\u003e77 %\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd class=\"p-head-table-spec\" width=\"50%\"\u003eOptimum heat transfer efficiency\u003c\/td\u003e\n      \u003ctd data-spec-id=\"RenOTCi\" colspan=\"2\" width=\"50%\"\u003e75 %\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd class=\"p-head-table-spec\" width=\"50%\"\u003eAverage particulate emissions rate\u003c\/td\u003e\n      \u003ctd data-spec-id=\"Emiss\" colspan=\"2\" width=\"50%\"\u003e1.6 g\/h\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd class=\"p-head-table-spec\" width=\"50%\"\u003eAverage CO \u003c\/td\u003e\n      \u003ctd data-spec-id=\"TauxCO\" colspan=\"2\" width=\"50%\"\u003e73 g\/h\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eClearance\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"5\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e \u003c\/td\u003e\n      \u003ctd colspan=\"2\" align=\"center\"\u003eCanada\u003c\/td\u003e\n      \u003ctd colspan=\"2\" align=\"center\"\u003eUnited-States\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e \u003c\/td\u003e\n      \u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eClearance – back wall\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e13 1\/4\"\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e13\"\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eClearance - corner\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e7 1\/4\"\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e7\"\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e7 1\/4\"\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e7\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eClearance – side wall\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e14\"\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e14\"\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e14\"\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e14\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"5\"\u003e\n        \u003cp class=\"small\"\u003e* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogs, flyers, magazines, and\/or websites).\u003c\/p\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"5\"\u003e\n        \u003cp class=\"small\"\u003e** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.\u003c\/p\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Drawings \u0026amp; Dimensions\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/OB03500_Techdraw.webp?v=1792965325\" alt=\"\" style=\"float: none;\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/OB03500_Techdraw_1.webp?v=1792965324\" alt=\"\"\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: left;\"\u003e\n  \u003cmeta charset=\"utf-8\"\u003e\n  \u003ch3\u003eWarranty\u003c\/h3\u003e\n  \u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/ChatGPT_Image_Jun_18_2026_02_25_23_PM.png?v=1781771144\" alt=\"\" width=\"206\" height=\"206\"\u003e\u003c\/p\u003e\n  \u003cp\u003eThe warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This warranty covers brand-new products only, which have not been altered, modified, or repaired since shipment from the factory. Proof of purchase (dated bill of sale), model name, and serial number must be supplied when making any warranty claim to your OSBURN dealer. This warranty applies to normal residential use only. This warranty is void if the unit is used to burn material other than cordwood (for which the unit is not certified by EPA) and void if not operated according to the owner's manual. Damages caused by misuse, abuse, improper installation, lack of maintenance, over-firing, negligence or accident during transportation, power failures, downdrafts, venting problems, or under-estimated heating areas are not covered by this warranty. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure. \u003c\/p\u003e\n  \u003cp\u003eThis warranty does not cover any scratch, corrosion, distortion, or discoloration. Any defect or damage caused by the use of unauthorized or other than original parts voids this warranty. An authorized qualified technician must perform the installation in accordance with the instructions supplied with this product and all local and national building codes. Any service call related to an improper installation is not covered by this warranty.\u003c\/p\u003e\n\n  \u003ch3\u003eAbout The Manufacturer\u003c\/h3\u003e\n  \u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/osburn_logo.png?v=1792423802\" alt=\"\"\u003e\u003c\/p\u003e\n  \u003cp\u003eOsburn is a Canadian hearth brand manufactured by Stove Builder International (SBI), a company specializing in residential heating appliances. Made in Québec, Osburn products reflect the region’s long experience with wood heating and cold-weather needs. The lineup includes wood stoves, fireplace inserts, wood fireplaces, cookstoves, and pellet stoves. Osburn designs appliances for a range of homes, with models offering different heating capacities, styles, and installation options. Many models use non-catalytic combustion technology to deliver efficient heat with reduced emissions. The company also develops heat-management solutions that can help distribute fireplace heat to other areas of the home. With a broad product range and Canadian manufacturing roots, Osburn brings together practical heating performance and considered design.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":53137455382815,"sku":"OB03500","price":3839.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/Osburn_3500_EPA_Certified_Freestanding_Extra_Large_Wood_Stove_with_Blower.png?v=1792966407","url":"https:\/\/ridgeflame.com\/products\/osburn-3500-epa-certified-freestanding-extra-large-wood-stove-with-blower","provider":"Ridge Flame","version":"1.0","type":"link"}