{"product_id":"duravent-directvent-pro-46dva-cl33-co-linear-kit-with-3-x-35-flex","title":"DuraVent DirectVent Pro 46DVA-CL33 Co-Linear Kit with 3\" x 35' Flex","description":"\u003cp dir=\"ltr\" data-path-to-node=\"1\"\u003e\u003cspan\u003eSimplify direct vent co-linear gas insert retrofits inside existing masonry chimneys with the DuraVent DirectVent Pro 46DVA-CL33 Co-Linear Kit with Flex.\u003c\/span\u003e\u003cspan\u003e Engineered for direct vent gas and propane stoves,\u003c\/span\u003e\u003cspan\u003e heaters,\u003c\/span\u003e\u003cspan\u003e and fireplace inserts,\u003c\/span\u003e\u003cspan\u003e this complete top-to-bottom venting package includes your choice of a 4\" x 6.\u003c\/span\u003e\u003cspan\u003e625\" High-Wind Termination Cap paired with two 3\" x 35' aluminum flex liners—color-coded Red for exhaust (A) and Green for fresh air intake (B).\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ci data-path-to-node=\"1\" data-index-in-node=\"479\"\u003eContractor Tip: Take advantage of the color-coded Red (exhaust) and Green (intake) 3\" x 35' flex runs during vertical chimney drops so you can immediately verify proper flue orientation at both the crown termination cap and the insert collar without tracing lines back up the chase—and always confirm appliance-specific clearances per the manufacturer's manual.\u003c\/i\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"2\"\u003e\u003cspan\u003ePart of the DirectVent Pro series (model 46DVA-CL33),\u003c\/span\u003e\u003cspan\u003e this UL,\u003c\/span\u003e\u003cspan\u003e CSA,\u003c\/span\u003e\u003cspan\u003e or Warnock Hersey listed co-linear relining kit eliminates guesswork by bundling matched flex lengths and high-wind termination hardware in a single SKU.\u003c\/span\u003e\u003cspan\u003e Backed by DuraVent's limited-lifetime warranty,\u003c\/span\u003e\u003cspan\u003e it ensures reliable draft stability,\u003c\/span\u003e\u003cspan\u003e weather protection,\u003c\/span\u003e\u003cspan\u003e and clean,\u003c\/span\u003e\u003cspan\u003e sealed combustion performance for masonry insert installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse when installing a direct vent co-linear insert into a masonry chimney.\u003c\/li\u003e\n\u003cli\u003eKit includes Choice of High-Wind Termination Cap and two pieces of Aluminum flex lengths - one Red (exhaust), and one Green (air intake).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ctable height=\"204\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCap Size\u003c\/td\u003e\n\u003ctd\u003eCap Style \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e46DVA-CL33\u003c\/td\u003e\n\u003ctd\u003e4\" x 6.625\"\u003c\/td\u003e\n\u003ctd\u003eHigh-Wind\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRed Flex Exhaust \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3\" x 35' (A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Intake\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cspan\u003e3\" x 3\u003c\/span\u003e\u003cspan\u003e5' (B)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDirect vent gas, propane stoves, heaters, and fireplaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSpecified by the appliance manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUL, CSA, or Warnock Hersey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLimited-lifetime warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/High-Wind_Termination_Cap_drawing_480x480_6ad00d12-f404-406a-9c66-6a362f1d75f9.jpg?v=1795603107\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e-Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation. For more Typical Installations kindly check our download links below.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/Typical_Installation_480x480_5f376b84-85a1-49e9-b33d-53b08f757ca3.jpg?v=1795601697\" alt=\"\"\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003ePlanning Your Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eFor vertical gas stove installations, measure the height from the stove outlet to the ceiling to determine the length of black pipe required. Select a ceiling support\/wall thimble cover or a cathedral ceiling support box.\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTo determine the length of galvanized pipe required, measure the ceiling thickness and the vertical rise in an attic or second story. Firestops are required at each floor level beyond the first-floor ceiling support\/wall thimble cover or cathedral ceiling support box. If an offset is required to avoid obstructions, use a pair of 45° elbows. For proper support, use elbow straps with offsets. Use wall straps for long vertical runs. An attic Insulation Shield is required in the attic.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMeasure the roof pitch. Select the proper flashing and storm collar. Determine the minimum height above the roof.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFor horizontal installations, check the appliance manufacturer’s instructions for the minimum rise and maximum horizontal run. A snorkel termination may be used if height restrictions prevent adequate rise above the appliance. Select the appropriate Horizontal Termination Cap (see appliance manufacturer installation instructions). To protect vinyl siding, select vinyl siding standoff. Check appliance manufacturer’s instructions for wall thimble and firestop requirements.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003eDesign Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe following design recommendations are general guidelines to assist in the design and selection of venting components for your installation. Always follow DuraVent Installation instructions enclosed with the cap or support box before installing your chimney system. Installation instructions can be viewed online at www.duravent.com, under Catalogs and Instructions. Important: Check the manufacturer’s rating plate and instruction manual to confirm that the DuraVent direct vent system is approved for use on the brand-name appliance you have selected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe inner and outer pipe diameters should match the outlet size of the appliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCheck the appliance manufacturer’s installation instructions to confirm which types of vent configurations are permitted (i.e. horizontal, vertical, chimney reline, etc.). Also, check for any venting restrictions such as maximum horizontal run, minimum and maximum vertical rise, maximum offset, etc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBe fire safe! Maintain at least the minimum clearances (air space) between the vent pipe and nearby combustibles, as specified in the appliance manufacturer’s installation instructions. Use proper support and bracing. Follow local building codes and have your venting system inspected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: rgb(255, 128, 0);\"\u003e\u003cspan style=\"color: rgb(48, 48, 48); font-size: 0.875rem;\"\u003eAbout The Manufacturer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(48, 48, 48); font-size: 0.875rem;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/Duravent_Logo.png?v=1789738697\" alt=\"\" width=\"411\" height=\"124\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDuraVent is a leading manufacturer of high-quality chimney and venting systems for residential and commercial applications. The company provides reliable solutions for wood, gas, pellet, and oil-burning appliances. Its products are rigorously tested to meet strict safety standards in the United States and Canada. DuraVent systems are engineered for durability, dependable performance, and long-term protection. Innovative features such as twist-lock connections help make installation faster, easier, and more secure. Trusted by homeowners and industry professionals, DuraVent is a recognized leader in venting technology.\u003c\/p\u003e","brand":"DuraVent","offers":[{"title":"Default Title","offer_id":53327380939039,"sku":"46DVA-CL33","price":765.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/DuraVent_46DVA-CL34_DirectVent_Pro_Co-Linear_Masonry_Reline_Kit_with_Flex.png?v=1795609637","url":"https:\/\/ridgeflame.com\/products\/duravent-directvent-pro-46dva-cl33-co-linear-kit-with-3-x-35-flex","provider":"Ridge Flame","version":"1.0","type":"link"}