{"product_id":"duravent-46dva-gk-directvent-pro-4-x-6-625-chimney-liner-termination-kit","title":"DuraVent 46DVA-GK DirectVent Pro 4\" x 6.625\" Chimney Liner Termination Kit","description":"\u003cp dir=\"ltr\" data-path-to-node=\"1\"\u003e\u003cspan\u003eConvert existing masonry chimney chases into sealed,\u003c\/span\u003e\u003cspan\u003e code-compliant direct vent terminations for gas and propane appliances with the DuraVent DirectVent Pro 4\" x 6.\u003c\/span\u003e\u003cspan\u003e625\" Chimney Liner Termination Kit.\u003c\/span\u003e\u003cspan\u003e Designed for direct vent gas and propane stoves,\u003c\/span\u003e\u003cspan\u003e heaters,\u003c\/span\u003e\u003cspan\u003e and fireplaces,\u003c\/span\u003e\u003cspan\u003e this galvanized top-termination assembly includes a Termination Connector and a 13\" x 18\" flashing plate with a 3\" (A) collar interface to bridge co-linear flex liners to a coaxial top cap.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ci data-path-to-node=\"1\" data-index-in-node=\"484\"\u003eContractor Tip: Remember that DirectVent Pro 4\" x 6 5\/8\" termination caps, 3\" flex liners, and co-linear flex connectors are sold separately—and always verify that this kit is tested and listed for your specific appliance model per the stove manufacturer's installation instructions before starting the reline.\u003c\/i\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"2\"\u003e\u003cspan\u003ePart of the DirectVent Pro series (model 46DVA-GK),\u003c\/span\u003e\u003cspan\u003e this UL,\u003c\/span\u003e\u003cspan\u003e CSA,\u003c\/span\u003e\u003cspan\u003e or Warnock Hersey listed galvanized termination kit delivers durable weather protection and tight exhaust\/intake separation at the chimney crown.\u003c\/span\u003e\u003cspan\u003e Backed by DuraVent's limited-lifetime warranty,\u003c\/span\u003e\u003cspan\u003e it offers a reliable,\u003c\/span\u003e\u003cspan\u003e installer-friendly transition for masonry fireplace insert and stove retrofits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKit includes Termination Connector and Flashing.\u003c\/li\u003e\n\u003cli\u003eDirectVent Pro 4” x 6 5⁄8” Termination Caps, 3” Flex, and Co-Linear Flex Connectors are sold separately.\u003c\/li\u003e\n\u003cli\u003eDirectVent Pro chimney liner termination kit must be tested and listed for each appliance.\u003c\/li\u003e\n\u003cli\u003eRefer to the stove manufacturer’s installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ctable height=\"204\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003eDimension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e46DVA-GK\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\"x6.625\"\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e3\u003c\/span\u003e\u003cspan\u003e\" (A) x 13\" (B) x 18\" width\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGalvanized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDirect vent gas, propane stoves, heaters, and fireplaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSpecified by the appliance manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUL, CSA, or Warnock Hersey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLimited-lifetime warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/Chimney_Liner_Termination_Kit_drawing_480x480_e3fc2809-fd2c-4df3-ba3a-8d703b80b10f.jpg?v=1795602724\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e-Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation. For more Typical Installations kindly check our download links below.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/Typical_Installation_480x480_5f376b84-85a1-49e9-b33d-53b08f757ca3.jpg?v=1795601697\" alt=\"\"\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003ePlanning Your Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eFor vertical gas stove installations, measure the height from the stove outlet to the ceiling to determine the length of black pipe required. Select a ceiling support\/wall thimble cover or a cathedral ceiling support box.\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTo determine the length of galvanized pipe required, measure the ceiling thickness and the vertical rise in an attic or second story. Firestops are required at each floor level beyond the first-floor ceiling support\/wall thimble cover or cathedral ceiling support box. If an offset is required to avoid obstructions, use a pair of 45° elbows. For proper support, use elbow straps with offsets. Use wall straps for long vertical runs. An attic Insulation Shield is required in the attic.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMeasure the roof pitch. Select the proper flashing and storm collar. Determine the minimum height above the roof.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFor horizontal installations, check the appliance manufacturer’s instructions for the minimum rise and maximum horizontal run. A snorkel termination may be used if height restrictions prevent adequate rise above the appliance. Select the appropriate Horizontal Termination Cap (see appliance manufacturer installation instructions). To protect vinyl siding, select vinyl siding standoff. Check appliance manufacturer’s instructions for wall thimble and firestop requirements.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003eDesign Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe following design recommendations are general guidelines to assist in the design and selection of venting components for your installation. Always follow DuraVent Installation instructions enclosed with the cap or support box before installing your chimney system. Installation instructions can be viewed online at www.duravent.com, under Catalogs and Instructions. Important: Check the manufacturer’s rating plate and instruction manual to confirm that the DuraVent direct vent system is approved for use on the brand-name appliance you have selected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe inner and outer pipe diameters should match the outlet size of the appliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCheck the appliance manufacturer’s installation instructions to confirm which types of vent configurations are permitted (i.e. horizontal, vertical, chimney reline, etc.). Also, check for any venting restrictions such as maximum horizontal run, minimum and maximum vertical rise, maximum offset, etc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBe fire safe! Maintain at least the minimum clearances (air space) between the vent pipe and nearby combustibles, as specified in the appliance manufacturer’s installation instructions. Use proper support and bracing. Follow local building codes and have your venting system inspected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: rgb(255, 128, 0);\"\u003e\u003cspan style=\"color: rgb(48, 48, 48); font-size: 0.875rem;\"\u003eAbout The Manufacturer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(48, 48, 48); font-size: 0.875rem;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/Duravent_Logo.png?v=1789738697\" alt=\"\" width=\"411\" height=\"124\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDuraVent is a leading manufacturer of high-quality chimney and venting systems for residential and commercial applications. The company provides reliable solutions for wood, gas, pellet, and oil-burning appliances. Its products are rigorously tested to meet strict safety standards in the United States and Canada. DuraVent systems are engineered for durability, dependable performance, and long-term protection. Innovative features such as twist-lock connections help make installation faster, easier, and more secure. Trusted by homeowners and industry professionals, DuraVent is a recognized leader in venting technology.\u003c\/p\u003e","brand":"DuraVent","offers":[{"title":"Default Title","offer_id":53327373631775,"sku":"46DVA-GK","price":376.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/DuraVent_46DVA-GK_DirectVent_Pro_4_x_6.625_Chimney_Liner_Termination_Kit.png?v=1795602832","url":"https:\/\/ridgeflame.com\/products\/duravent-46dva-gk-directvent-pro-4-x-6-625-chimney-liner-termination-kit","provider":"Ridge Flame","version":"1.0","type":"link"}