{"product_id":"46dva-kcb","title":"DuraVent 46DVA-KCB DirectVent Pro Horizontal Co-Linear Vent Kit for Direct Vent Inserts","description":"\u003cp dir=\"ltr\" data-path-to-node=\"1\"\u003e\u003cspan\u003eVent approved direct vent gas and propane fireplace inserts horizontally out the back of a suitable masonry chimney when a full vertical chimney reline is impractical with the DuraVent DirectVent Pro Horizontal Co-Linear Vent Kit for Direct Vent Inserts.\u003c\/span\u003e\u003cspan\u003e Designed for direct vent gas and propane stoves,\u003c\/span\u003e\u003cspan\u003e heaters,\u003c\/span\u003e\u003cspan\u003e and fireplace inserts,\u003c\/span\u003e\u003cspan\u003e this rear-exit venting package includes a 4\" x 6.\u003c\/span\u003e\u003cspan\u003e625\" Co-Linear Horizontal Termination cap,\u003c\/span\u003e\u003cspan\u003e two 10' aluminum flex lengths—available in twin 3\" x 3\" (model 46DVA-HCL33) or asymmetric 3\" x 4\" (model 46DVA-HCL34) configurations—plus all required hardware for secure flex attachment.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ci data-path-to-node=\"1\" data-index-in-node=\"636\"\u003eContractor Tip: Before coring through the rear masonry wall, verify that both your fireplace insert and local building codes approve horizontal rear-chimney termination, confirm whether your appliance collar requires the 3\" x 3\" (46DVA-HCL33) or 3\" x 4\" (46DVA-HCL34) flex configuration, and maintain all exterior terminal clearances from windows, doors, and grade per the appliance manufacturer's installation manual.\u003c\/i\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"2\"\u003e\u003cspan\u003ePart of the DirectVent Pro series (models 46DVA-HCL33 and 46DVA-HCL34),\u003c\/span\u003e\u003cspan\u003e this UL,\u003c\/span\u003e\u003cspan\u003e CSA,\u003c\/span\u003e\u003cspan\u003e or Warnock Hersey listed horizontal co-linear kit provides a clean,\u003c\/span\u003e\u003cspan\u003e sealed exhaust and fresh-air intake path directly out the back of existing masonry chases.\u003c\/span\u003e\u003cspan\u003e Backed by DuraVent's limited-lifetime warranty,\u003c\/span\u003e\u003cspan\u003e it offers dependable draft performance and weather-tight exterior termination for rear-vented insert retrofits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse when venting an approved appliance horizontally through the back of a suitable masonry chimney.\u003c\/li\u003e\n\u003cli\u003eKit includes Co-Linear Termination, Two 10’ Aluminum Flex Lengths (3x3 or 3x4), and Hardware for Flex Attachment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ctable height=\"204\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCap Size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e46DVA-HCL33\u003c\/td\u003e\n\u003ctd\u003e4\"  x 6.625\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e46DVA-HCL34\u003c\/td\u003e\n\u003ctd\u003e4\" x 6.625\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplications\u003c\/td\u003e\n\u003ctd\u003eDirect vent gas, propane stoves, heaters, and fireplaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSpecified by the appliance manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListings\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, or Warnock Hersey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited-lifetime warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/Horizontal_ventkit_drawing_480x480_1fc4e01b-3463-4ba6-a774-dd22bb750648.jpg?v=1795610441\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e-Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation. For more Typical Installations kindly check our download links below.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/Typical_Installation_480x480_5f376b84-85a1-49e9-b33d-53b08f757ca3.jpg?v=1795601697\" alt=\"\"\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003ePlanning Your Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eFor vertical gas stove installations, measure the height from the stove outlet to the ceiling to determine the length of black pipe required. Select a ceiling support\/wall thimble cover or a cathedral ceiling support box.\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTo determine the length of galvanized pipe required, measure the ceiling thickness and the vertical rise in an attic or second story. Firestops are required at each floor level beyond the first-floor ceiling support\/wall thimble cover or cathedral ceiling support box. If an offset is required to avoid obstructions, use a pair of 45° elbows. For proper support, use elbow straps with offsets. Use wall straps for long vertical runs. An attic Insulation Shield is required in the attic.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMeasure the roof pitch. Select the proper flashing and storm collar. Determine the minimum height above the roof.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFor horizontal installations, check the appliance manufacturer’s instructions for the minimum rise and maximum horizontal run. A snorkel termination may be used if height restrictions prevent adequate rise above the appliance. Select the appropriate Horizontal Termination Cap (see appliance manufacturer installation instructions). To protect vinyl siding, select vinyl siding standoff. Check appliance manufacturer’s instructions for wall thimble and firestop requirements.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003eDesign Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe following design recommendations are general guidelines to assist in the design and selection of venting components for your installation. Always follow DuraVent Installation instructions enclosed with the cap or support box before installing your chimney system. Installation instructions can be viewed online at www.duravent.com, under Catalogs and Instructions. Important: Check the manufacturer’s rating plate and instruction manual to confirm that the DuraVent direct vent system is approved for use on the brand-name appliance you have selected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe inner and outer pipe diameters should match the outlet size of the appliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCheck the appliance manufacturer’s installation instructions to confirm which types of vent configurations are permitted (i.e. horizontal, vertical, chimney reline, etc.). Also, check for any venting restrictions such as maximum horizontal run, minimum and maximum vertical rise, maximum offset, etc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBe fire safe! Maintain at least the minimum clearances (air-space) between the vent pipe and nearby combustibles, as specified in the appliance manufacturer’s installation instructions. Use proper support and bracing. Follow local building codes and have your venting system inspected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: rgb(255, 128, 0);\"\u003e\u003cspan style=\"color: rgb(48, 48, 48); font-size: 0.875rem;\"\u003eAbout The Manufacturer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(48, 48, 48); font-size: 0.875rem;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/Duravent_Logo.png?v=1789738697\" alt=\"\" width=\"411\" height=\"124\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDuraVent is a leading manufacturer of high-quality chimney and venting systems for residential and commercial applications. The company provides reliable solutions for wood, gas, pellet, and oil-burning appliances. Its products are rigorously tested to meet strict safety standards in the United States and Canada. DuraVent systems are engineered for durability, dependable performance, and long-term protection. Innovative features such as twist-lock connections help make installation faster, easier, and more secure. Trusted by homeowners and industry professionals, DuraVent is a recognized leader in venting technology.\u003c\/p\u003e","brand":"DuraVent","offers":[{"title":"Default Title","offer_id":53327995142431,"sku":"46DVA-KCB","price":504.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/5022\/9802\/files\/DuraVent_46DVA-HCL34_DirectVent_Pro_Horizontal_Co-Linear_Vent_Kit_for_Direct_Vent_Inserts.png?v=1795610834","url":"https:\/\/ridgeflame.com\/products\/46dva-kcb","provider":"Ridge Flame","version":"1.0","type":"link"}